Throughput
- Up to 180 tests per hour;
- Up to 300 tests per hour with ISE unit.
Reagent system
- Rotor with 24 positions for 25 ml bottles and 8 positions for 5 ml bottles.
All positions can be assigned as R1, R2 and R3.
Adapters for 5 ml bottles in 25 ml positions.- 5 pairs of 25 ml positions can be used for 50 ml bottles;
- Reagent 1 volume 110 - 400 µl;
- Reagent 2 volume 0 - 180 µl;
- Reagent 3 volume 0 - 180 µl;
- Reagent disk compartment is cooled to approx. 12°C below ambient temperature;
- Preheated reagent needle with level detection and integrated mixer;
Typical reagent consumption 250 µl per test.
Sample system up↑
- Sample rotor containing:
- Outer segment with 51 positions for samples and/or controls;
- Inner segment for calibrators, controls, stats, blank and wash solution;
Stat and pediatric functionality;
- Continuous loading;
- All positions can contain 5 ml primary tubes or sample cups;
- Sample volume 1 - 30 µl per test, programmable in steps of 0.1 µl;
- Sample probe with level detection and integrated mixer;
- Optional rotor for KABE and SARSTEDT sample tubes.
Sample predilution
(MULTIPLE REAGENT MODE ONLY)
- Pre-programme ratios selectable from 1:2 to 1:00 with 3 diluents;
- Automatic parent calibrator dilution.
PIPETTING SYSTEM
Reagent syringe 1000 µl;
Sample syringe 100 µl.
- Semi-disposable rotor with 48 cuvettes. Path length 7mm;
- > 10.000 tests per rotor;
- Min. measuring volume 220 µl;
Measuring temperature 37 °C, controlled by Peltier elements
- Cuvette-washing with 4 x 500 µl of water. The unit is equipped with liquid sensors. Waste is separated into diluted and concentrated (sample/reagent mixture and optional ISE-unit) waste. Cuvettes are dried before use.
- Quarts-iodine lamp 12V-20W.
- Optical unit with an 8 position filter wheel;
- Automatic wavelength selection by 8-position filter wheel (340, 376, 405, 436, 505, 546, 578 and 620 nm);
- Other wavelenghts available on request;
- Half bandwidth 8 to 12 nm.
- -0.1 to 3.0 Absorbance
- Kinetic measurement with linearity check;
- Bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction;
- Two point measurement;
- Graphic plot of all measuring points;
- Automatic rerun with sample reduction;
- Non-linear calibration curves.
- 15 - 32°C;
- Maximum humidity 80%.
- Reagent Absorbance (bichromatic) before sample addition;
- Kinetic during 7 minutes after sample addition;
- End Point (Bichromatic) 11.5 minutes after sample addition;
- Kinetic can contain two points for two-point measurements.
- Reagent Absorbance (bichromatic) before sample addition;
- Kinetic 1 for 4.5 minutes after sample addition (can be used as sample blank for Kinetic 2);
- Kinetic 2 for 4 minutes after reagent 2 addition;
- Kinetic 1+2 for 8.5 minutes after sample addition;
- Sample blank (bichromatic) before reagent 2;
- Endpoint (bichromatic) 4.5 minutes after sample addition or 11.5 minutes after sample addition;
- Kinetic 1, Kinetic 2 or Kinetic 1 + 2 can contain a minimum measuring time or two points for two-point measurements.
- Additional timings available for three reagent system.
- Prozone check for immunology tests;
- Cut-off declaration.
- Up to 15 different controls can be defined, 3 per test;
- Westgard rules;
- Levy-Jennings plots.
- CE;
- CB.
- In confirmity with CE/IVD requirements;
- Other langauges on request.
- 74 kg.
- 115 x 49 x 56 cm (W x H excl. Monitor x D)
Bar code reader
- Hand held CCD bar code reader (can read all common bar codes) used for test requisition and sample identification.
concentrated waste
computer
. Pentium 100MHz . EGA Monitor 640x480 pixels. Hard Disk: 1GB. Floppy: 3½" (1.44MB) .CD ROM drive . Windows '95 or '98 . Serial ports: 1 for analyzer and 1 for host
Minimum requirements:
printer
- The application supports two printers simultaneously; one for patient reports and one for calibration and system data;
- Most printers supported by Windows can be connected.
ISE unit
2. up↑
Na, K and Cl measurements;
CO
|
|
|
|
|
|